Made to Order or imported lines subject to availability. 

SC802 Intumescent steel coating is a very low VOC, borate free, APEO free, water based, thin film intumescent coating for the protection of structural steelwork. SC802 contains no substances of very high concern.
SC802 provides up to 60 minutes fire resistance to ā€˜I’ section beams, columns, hollow section columns and cellular beams.

FEATURES:

  • Fully tested and certified in accordance with BS476: Part 21: 1987
    • Certifire CF5420
  • Waterborne technology
  • Very low VOC:
    • 84% below IEQ-3 Indoor Air Quality requirement of ≤ 100 g/litre
  • Halogen-free formulation
  • Low odour, user friendly
  • No topseal required for interior, dry non-decorative exposures
  • Rapid dry to recoat / topcoat (refer to dry time and ventilation tables overleaf)
  • Other Certification:
    • Fire Propagation / Spread of Flame
      • BS476: 6/7 Class 0
    • EN13823 (SBI) and IMO smoke / toxicity
    • Certifire fully tested on cellular beams